1.SC Codes
416
ï‚· Replace the cover guide motor (right).
ï‚· Replace the cover guide (right) HP sensor.
ï‚· Replace the master control board.
ï‚· Replace the motor harness.
ï‚· Replace the sensor harness.
SC752-22
Error Name
Perfect Binder: Cover Guide (Right) Sensor Error
Pattern
D
Error Condition
The cover guide HP sensor (right) and cover guide (right) open sensor went ON at the same time.
Major Cause
ï‚· Cover guide HP sensor (R) defective
ï‚· Cover guide open sensor (right)
ï‚· Harness connector loose, damaged, or defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the cover guide (right) HP sensor.
ï‚· Replace the cover guide open sensor (right).
ï‚· Replace the master control board.
ï‚· Replace the sensor harness.
SC752-23
Error Name
Perfect Binder: Right Cover Guide Release Position Late Error
Pattern
D
Error Condition
During movement toward the right cover guide open position, the cover guide open sensor (right) did
not go ON after the cover guide motor (right) had operated long enough for 3000 ms of movement.