1.SC Codes
619
SC900
SC900-00
Error Name
Electrical Total Counter Error
Pattern
A
Error Condition
The total counter contains data that is not a number.
Major Cause
ï‚· NVRAM is of the incorrect type.
ï‚· NVRAM is defective or corrupted.
ï‚· Unexpected error due to external factors.
ï‚· When PRT received signals at SRM, the requested count did not complete.
Solution
Replace the NVRAM.
SC910-00
Error Name
External Controller Error 1
Pattern
C
Error Condition
Notification from an external application (external controller)
Major Cause
Depends on the specifications of the external controller.
Solution
Turn the main power OFF and ON.
SC910-01
Error Name
External Controller Error 1