1.SC Codes
481
Error Condition
The glue abnormal temperature thermistor detected a temperature of less than 5 degrees for 1 sec., or
more than 10 sec. after power on. However, if the thermistor detected less than 100 degrees after
measuring temperature at start up, temperature is checked again after 50 sec.
Major Cause
ï‚· Glue abnormal temperature thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.
After the repairs, cancel the low performance mode, and then turn the power off/on.
SC753-48
Error Name
Perfect Binder: Glue level thermistor disconnect error
Pattern
B
Error Condition
ï‚· The AD value of the glue level thermistor was above 991 LSB for 10 sec.
ï‚· Temperature adjustment mode stops if glue level sensor detects the temperature remaining below
99 degrees for more than 10 sec.
ï‚· Because temperature adjustment began in another mode, the adjustment stopped when the error
was detected and error detection stopped.
ï‚· Error detection will not operate at temperature adjustment stop.
Major Cause
ï‚· Glue level thermistor defective
ï‚· Glue heater defective
ï‚· Slave board defective
Solution
ï‚· Reconnect the connector.
ï‚· Replace the gluing unit.
ï‚· Replace the slave board.