RIGOL 2 Command System
2-136 MSO2000A/DS2000A Programming Guide
:MEASure:COUNter:SOURce
Syntax
:MEASure:COUNter:SOURce <sour>
:MEASure:COUNter:SOURce?
Description
Set or query the measurement source of the frequency counter or disable the frequency counter
measurement.
Parameter
Name Type Range Default
<sour> Discrete
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|D11|D12|D13|D14|D
15|CHANnel1|CHANnel2|EXT|OFF}
OFF
Return Format
The query returns D0, D1, D2, D3, D4, D5, D6, D7, D8, D9, D10, D11, D12, D13, D14, D15, CHAN1,
CHAN2, EXT or OFF.
:MEASure:COUNter:VALue?
Syntax
:MEASure:COUNter:VALue?
Description
Query the measuremenmt result of the frequency counter. The unit is Hz.
Explanation
Before using this command, enable the frequency counter (refer to the
:MEASure:COUNter:SOURce
command).
Return Format
The query returns the current measurement value in scientific notation.