2 Command System RIGOL
MSO2000A/DS2000A Programming Guide
2-287
:TRIGger:PATTern
:TRIGger:PATTern:LEVel
:TRIGger:PATTern:PATTern
:TRIGger:PATTern:SOURce
:TRIGger:PATTern:LEVel
Syntax
:TRIGger:PATTern:LEVel <chan>,<level>
:TRIGger:PATTern:LEVel? <chan>
Description
Set or query the trigger level of each channel in pattern trigger. The unit is the same with the current
amplitude unit.
Parameter
Name Type Range Default
<chan> Discrete
{D0|D1|D2|D3|D4|D5|D6|D7|D8|D9|D10|
D11|D12|D13|D14|D15|CHANnel1|CHANnel2}
CHANnel1
<level> Real
When <chan> is CHANnel1 or CHANnel2:
-5×VerticalScale–OFFSet to +5×VerticalScale–OFFSet
When <chan> is any of D0-D15: -20V to 20V
0
Note: For the VerticalScale, refer to the :CHANnel<n>:SCALe command. For the OFFSet, refer to
the
:CHANnel<n>:OFFSet command.
Return Format
The query returns the trigger level in scientific notation.