Chapter 8
BREAKDOWN INFORMATION
- 41 -
English
C824153200.fmIDM
E62 "Self-learning" mode alarm
The maximum number of steps
in the "Self-learning" mode has
been reached.
Turn the machine off and restart
it Repeat the "Self-learning"
procedure
E70 Function disabled alarm
A function was selected from
the control panel that is not
enabled for the type of reel
carriage installed on the
machine or the keyboard block
is on
Select another function from the
control panel or release the
keyboard
E90 Low voltage alarm
Voltage is lower than the
allowed minimum
When the machine is turned
off, message appears even in
absence of anomalies.
Reset the voltage value
E91 High voltage alarm
Voltage is higher than the
maximum allowed value
Reset the voltage value Turn
the machine off and restart it
Table 8.1: Alarm list
Alarm Problem Cause Solution
Evers GmbH Graf-Zeppelin-Str. 10 46149 Oberhausen Telefon +49 208 99475-0 Telefax +49 208 99475-31 evers@eversgmbh.de eversgmbh.de