- 40 -
English
C824153200.fmIDM
Chapter 8
BREAKDOWN INFORMATION 2
8.1. ALARM MESSAGES
In the event of a breakdown during operations the machine stops automatically and
alarm messages appear on the display.
The table lists the displayed messages, the type of problem, the cause and possible
solutions.
For these operations a precise technical skill or ability is required and must
therefore be exclusively performed by qualified personnel with certified experi-
ence acquired in the specific field.
Table 8.1: Alarm list
Alarm Problem Cause Solution
E10 Transpallet photocell alarm
An obstacle has been detected
on the platform loading/
unloading ramp
Remove the obstruction and
press button "Cycle stop"
E30 Rotary table inverter alarm Inverter overload
Remove the overload cause.
Turn the machine off and restart
it
E31 Carriage inverter alarm Inverter overload
Remove the overload cause.
Turn the machine off and restart
it
E32 Film pre-stretch inverter alarm Inverter overload
Remove the overload cause.
Turn the machine off and restart
it
E34 Inverter alarm. Inverter overheating
Remove the overload cause.
Turn the machine off and restart
it
E41 Serial communication alarm Electronic anomaly Contact the service centre
E42
Cycle parameter initialisation
alarm
Electronic anomaly Contact the service centre
E43 Data writing alarm Electronic anomaly Contact the service centre
E44 Data writing alarm Electronic anomaly Contact the service centre
E46 Serial communication alarm Electronic anomaly Contact the service centre
E47 Serial communication alarm Electronic anomaly Contact the service centre
E61 Table blocked alarm
A breakdown or obstacle block
table rotation
Remove the cause of the
failure. Turn the machine off
and restart it