Installation and Configuration
Installing the System
R&S VENICE S
74
User Manual | 2906.2506.02 - 01
6.
Loop and secure the power cable using the retention strap.
7. Connect a network cable to the Ethernet connector “eno8303” or
“eno8403” depending on your installation routine. For details see chapter
“Network Configuration” on page 77.
With “eno8303” the IP address is assigned automatically. With
“eno8403” the default IP is 10.0.0.8.
Data Loss/Corrupt Data
In the event of a power failure the device will be abruptly switched off. This
can result in corrupt data, loss of data, and equipment damage.
Connect the system to an uninterruptible power supply (UPS) redun-
dantly on two phases.
Use only original Rohde & Schwarz certified parts.