5
Settings Used on this Instrument
Indication (Parameter)
Value Explanation
Motion Ctrl Mode
These parameters set how the motion sensors control the sound.
O
Turns o the motion sensor control.
Normal
Tilting the AE-30 controls the functions that are assigned in the Assign parameters.
The tilt detection range is set in Motion_1 Setting and Motion_2 Setting.
Vibrato
Lets you controls the pitch when you make cyclic changes to how the AE-30 is tilted.
Gives a vibrato-like eect when you repeatedly move the AE-30 up and down.
Motion_1 Setting
Motion_2 Setting
These parameters congure the detection range of the motion sensors.
Elevation Tilt
Tilt Full
Tilt Left Tilt Right
0
64
127
MIDI controller value
0–180 °
0
127127
-90–90°
64
1270
-90–90°
0
127
-90–0°
0
127
0–90°
Elevation
The motion of lifting the AE-30 up is used. This works through the range of tilting the
instrument up to 180º upwards.
Tilt
The motion of tilting the AE-30 either to the left or to the right is used. This works through
the range of tilting the instrument up to 90º to the left or right.
Tilt Full
The motion of tilting the AE-30 either to the left or to the right is used. The base value is
when the instrument is tilted 90º to the left, and this works through the range of tilting the
instrument up to 90º to the right.
Tilt Left
The motion of tilting the AE-30 to the left is used. This works through the range of tilting
the instrument up to 90º to the left.
Tilt Right
The motion of tilting the AE-30 to the right is used. This works through the range of tilting
the instrument up to 90º to the right.
Motion Sense (Vib) 1–10
Sets the sensitivity when Motion Ctrl Mode is set to “Vibrato.” Increase this value if you want
to make the eect easier to apply; lower this value if the eect is too strong.
Bend Range Motion Dn
Bend Range Motion Up
0–2400 (cent)
Sets the bend range in cents, when “Bend Up/Down” is assigned to the motion control.
* This is enabled when Bend Range Source is “System.”
Asgn Src Breath
System, Scene
Selects whether to use the system settings (System) or the settings in each scene (Scene)
for the Assign or MIDI parameter that is assigned to the breath control.
Asgn Src Bite
Selects whether to use the system settings (System) or the settings in each scene (Scene)
for the Assign or MIDI parameter that is assigned to the bite control.
Asgn Src Lever
Selects whether to use the system settings (System) or the settings in each scene (Scene)
for the Assign or MIDI parameter that is assigned to the thumb lever.
Asgn Src Thumb Pad
Selects whether to use the system settings (System) or the settings in each scene (Scene)
for the Assign or MIDI parameter that is assigned to the thumb pad.
Asgn Src Motion
Selects whether to use the system settings (System) or the settings in each scene (Scene)
for the Assign or MIDI parameter that is assigned to the motion control.
Asgn Src S1/S2
Selects whether to use the system settings (System) or the settings in each scene (Scene)
for the Assign or MIDI parameter that is assigned to the [S1]/[S2] buttons.
Asgn Src Key
Selects whether to use the system settings (System) or the settings in each scene (Scene)
for the Assign or MIDI parameter that is assigned to the performance keys.
Harmony Source
Selects whether to use the system harmony settings (System) or the harmony settings in
each scene (Scene).