BRP-Rotax
MAINTENANCE MANUAL LINE
Points of Inspection
Interval Operating hours Chapter
Reference
Signa-
ture
* no periodic maintenance require-
ment after the first 25 hours of
operation
25* 50 100 200 600 1000
chips and inspect components for wear
and/or missing material.
Perform filter mat inspection:
Findings.
__________________________
Inspection of
the oil filter
components
(4
use of leaded fuel more than 30% of operation.
7) Visual inspection of the engine
General visual inspection of the engine
for damage or abnormalities. Check
cooling air duct and cooling fins of the
cylinders for obstruction, cracks, wear
and good condition. Take note of
changes caused by temperature
influence.
X X X X X 12–20–00
Visual
inspection
Inspect temperature sensors and oil
pressure sensor for secure fit and signs
of wear.
X X X
Inspect all coolant hoses of the engine
for damage, including leakage, harden-
ing from heat, porosity, loose connec-
tions and secure attachment. Verify
routing is free of kinks and restrictions.
X X X X X 12–20–00
Leakage
check
Carry out visual inspection of leakage
bore at the base of the water pump for
signs of leakage.
X X X X X 12–20–00
Leakage
check
Inspect the expansion tank for damage
and abnormalities. Check coolant level,
replenish as necessary. Inspect radia-
tor cap. Inspect protection rubber on
expansion tank base for correct fit.
X X X X X 12–20–00
Expansion
tank, radiator
cap
Inspect the overflow bottle for damage
and abnormalities. Verify coolant level,
replenish as necessary. Inspect line
from expansion tank to overflow bottle
for damage, leakage and clear pas-
sage. Inspect venting bore in cap of
overflow bottle for clear passage.
X X X X X 12–20–00
Overflow
bottle
Effectivity: 912 i Series
Edition 2/Rev. 0
05–20–00
Page 11
September 01/2018