7.5
AS20WRF/BRF Thermostat – Setting the Temperature
The AS20WRF/BRF Thermostat comes pre-programmed with a default setback schedule for weekdays and
weekends. The instructions that follow the graphical representation of these schedules allow the installer
to choose the target temperatures for each of these periods.
Prior to pairing, the AS20WRF/BRF Thermostat must be set to the desired conguration. It can be
congured as a programmable thermostat (default) or a digital thermostat. The default conguration,
, will operate as either a standalone thermostat or the manager of a thermostat group. To
operate the AS20 as a dependent in a group, it must be congured before pairing.
Default Weekday Schedule
Default Weekend Schedule
Heating Mode Default Temp. Active Heating Mode
Schedule Block
1 2 3 4
22
19
17
Time (24hr clock) 00:00 07:00 09:00 17:00 23:00
Heating Mode Default Temp. Active Heating Mode
Schedule Block
1 2 3 4
22
19
17
Time (24hr clock) 00:00 08:00 09:00 17:00 23:00
Section 7
Setting Device Parameters