7.12
Function
Parameters
Description
Default Value
Password Required
Heating Control ± 1.0°F [± 0.5°C]
TPI Time Proportional & Integral (TPI)
± 0.50°F [± 0.25°C] ON/OFF – Increment Resolution
± 1.0°F [± 0.5°C] ON/OFF – Increment Resolution
Room Temperature Oset 0°F [0°C]
- 6.0°F to + 6.0°F
Thermostat reads Actual ± Oset Temperature
- 3.0°C to + 3.0°C
Sensor Probe
No Sensor
Connected
No Sensor Connected No sensor connected to S1/S2 on thermostat
Sensor Probe Connected A sensor is connected to S1/S2 on thermostat
Sensor Probe used as an air
sensor or oor sensor
Air Sensor
Air Sensor Sensor for remote air temperature
Floor Sensor Sensor for radiant oor temperature
Cooling Control ± 1.0°F [± 0.5°C]
± 0.50°F [± 0.25°C] ON/OFF – Increment Resolution
± 1.0°F [± 0.5°C] ON/OFF – Increment Resolution
Valve Protection Enabled
Disabled ARV10RFM Protection Disabled
Enabled ARV10RFM Protection Enabled
Floor Sensor Limit for Cooling 45°F [7°C]
45°F to 113°F
Minimum oor temperature for cooling
7°C to 45°C
Floor Sensor High Limit
Temperature
52°F [11°C]
52°F 113°F
Maximum oor temperature for heating
11°C to 45°C
Floor Sensor Low Limit
Temperature
50°F[10°C]
45°F to 113°F
Minimum oor target temperature
7°C to 45°C
Do you allow to unlock from
your thermostat side?
Yes
Yes
Controls permission to unlock the parameters menu from
the thermostat user interface screen
No
Section 7
Setting Device Parameters
AS20WRF/BRF Thermostat – SALUS Smart Home
Application - Advanced Functions & Parameters