Version 09/2015, Rev. 1.3 of 02/03/2017
Translation of the original operating manual, WZG6001-e150401
Pos: 119 /100 Sigma/1 00 BA Zentr ifugen Sigma (Sta ndardmodule)/0 60 Betrieb_Spin control L+S/Spi ncontrol L (Zent6)/ 060-0030- 0020 Manuelle r Betrieb @ 27 \mod_140531925419 2_68.do cx @ 192647 @ 3 @ 1
6.3.2 Manual mode
Pos: 120 /100 Sigma/1 00 BA Zentr ifugen Sigma (Sta ndardmodule)/0 60 Betrieb_Spin control L+S/Spi ncontrol L (Zent6)/ 060-0030- 0020-0010 Sta rten einer Ze ntrifugation @ 27 \mod_140531925 5424_68.docx @ 192661 @ 4 @ 1
6.3.2.1 Starting a centrifugation run
The centrifuge is ready for operation when the start key is illuminated.
Press the start key in order to start a centrifugation run.
Pos: 121 /010 Unive rsalmodule/ Leerzeile @ 0 \mod_120211624 4500_0.do cx @ 114 @ @ 1
Pos: 122 /100 Sigma/1 00 BA Zentr ifugen Sigma (Sta ndardmodule)/0 60 Betrieb_Spin control L+S/Spi ncontrol L (Zent6)/ 060-0030- 0020-0020 Unte rbrechen einer Ze ntrifugation @ 27\mod_1405 319256724_6 8.docx @ 19267 5 @ 4 @ 1
6.3.2.2 Interrupting a centrifugation run
Press the stop key in order to interrupt a centrifugation run. The centrifugation
run will be terminated prematurely.
Quick stop
Press the stop key for more than two seconds.
The centrifuge decelerates with the maximum deceleration curve.
After a quick stop, the centrifuge lid must be opened before a new centrifugation
run can be started.
A quick stop can also be triggered during a normal deceleration, e.g. in order to
speed up the deceleration.
When a quick fast in the lower right-hand
corner of the display.
Pos: 123 /010 Unive rsalmodule/ Leerzeile @ 0 \mod_120211624 4500_0.do cx @ 114 @ @ 1
Pos: 124 /100 Sigma/1 00 BA Zentr ifugen Sigma (Sta ndardmodule)/0 60 Betrieb_Spin control L+S/Spi ncontrol L (Zent6)/ 060-0030- 0020-0030 Unte rbrechen eines Bremsvorga ngs @ 27\mod_14 05319258018_ 68.docx @ 192 689 @ 4 @ 1
6.3.2.3 Interrupting a deceleration process
Press the start key during a deceleration process in order to interrupt it and to
restart the centrifuge.
Pos: 125 /010 Unive rsalmodule/ Leerzeile @ 0 \mod_120211624 4500_0.do cx @ 114 @ @ 1
Pos: 126 /100 Sigma/1 00 BA Zentr ifugen Sigma (Sta ndardmodule)/0 60 Betrieb_Spin control L+S/Spi ncontrol L (Zent6)/ 060-0030- 0020-0040 Aus wahl, Anzeige u nd Änderung v on Daten @ 27\ mod_1405319 259317_68.do cx @ 192703 @ 4 @ 1
6.3.2.4 Selection, display, and modification of data
Turn the function knob in order to select a field. The selected field will be
preceded by the indication "set", "run", or "save".
Press the function knob. The indication ("set", "run", or "save") flashes and the
modification mode is active.
Turn the function knob in order to modify the set value of the selected field.
Press the function knob again to confirm the input and to quit the
modification mode
The process will be interrupted if the stop key is pressed or after 60 seconds
without any further input.