Maintenance
46 02.00 | PGL-plus-P | Assembly- and Operating Manual | en | 1508050
7.2 Maintenance intervals
The product is maintenance-free provided that the ambient and
operating conditions are met, }3 [
/
16].
Although the product is maintenance-free, it should be regularly
inspected visually to ensure that it functions properly.
In the case of extreme ambient and operating conditions, such as
• Contaminated environments
• High temperatures
• Operations using compressed air quality that does not meet ISO
8573-1: 7:4:4
the product must be cleaned, checked for damage and wear,
relubricated and the seals replaced as required.
This will help achieve a long service life even under extreme
ambient and operating conditions.
Perform all maintenance work without a gripped workpiece!
NOTICE
Material damage due to hardening lubricants!
Lubricants harden more quickly at temperatures above 60°C,
leading to possible product damage.
• Reduce the lubricant intervals accordingly.