6. Push the driver(8) together and press the pinion(6) into the
drive housing(3).
7. Secure the cover(12) with the screws(121).
8. Insert the seal(113) into the cylinder piston(27).
9. Tighten the screw(131).
10. Insert jaws(2) into the guide housing(1).
IMPORTANT!Observe the installation position of the jaws(2)
in the housing(1).
11. Insert the magnet holder(31) into the jaw(2) and fasten it
with the screw(119).
12. Insert the flat gasket(16).
13. Secure the cover(11) with the screws(116).
14. Insert the gaskets(14).
15. Press base jaws(4) into jaws(2) and secure with screw(13).
16. Assemble the guide housing(1) and drive housing(3) and
secure with the screws(115).
17. Insert the flat gasket(17) into the cover(25).
18. CAUTION!The components are under spring tension! Place
the spring(24) in the cylinder piston(27) and push it carefully
in the direction of the drive housing(3). Tighten the
screw(131).
19. Secure the cover(25) with screws(128, 129).
20. Mount product onto the system/machine.
21. Connect all compressed air lines.