| 3 - User manual
To cascade the word clock:
Connect the cable from the word clock in input of the next Base Station to the word
clock out output of the previous Base Station.
The Base Station has been connected to word clock.
Word clock scenarios for digital audio
The Base Station supports two clock rates: 48 kHz and 96 kHz.
You can use either the internal word clock on the Base Station or connect an external word
clock.
An external word clock can also be forwarded to a downstream device via the word clock
output. This feature allows you to cascade up to 8 Base Station devices.