Communication via Ethernet
MOVITOOLS® MotionStudio – Operation
9.9.2 Configuring the communication channel via Ethernet
Do the following to configure a communication channel for Ethernet:
1. Click on "Configure communication plugs" [1] in the toolbar.
This opens the "Configure communication plugs" window.
2. From the list [1], select "Ethernet" as the communication type.
In the example, "ETHERNET" is activated as the communication type for the first
communication channel [2].
3. Click [Edit] [3] in the right section of the window.
This will display the settings for the "Ethernet" communication type.
4. Set up the SMLP protocol. Select the "SMLP settings" tab.
SMLP stands for Simple MOVILINK
®
Protocol. This is the SEW-EURODRIVE unit
protocol and is transmitted directly via TCP/IP.
64341AXX
[1] "Configure communication plugs" symbol
64351AEN
[1] "Type of communication" dropdown menu
[2] "Activate" checkbox
[3] [Edit] button