118
Manual – DFE32B Fieldbus Interface PROFINET IO
9
Communication via Ethernet
MOVITOOLS® MotionStudio – Operation
5. Set the parameters. Follow the instructions described in the section "Setting commu-
nication parameters for SMLP".
9.9.3 Setting communication parameters for SMLP
Proceed as follows to set the Ethernet communication parameters:
1. Change the set communication parameters if necessary. When doing so, refer to the
detailed description of the communication parameters.
NOTE: During a unit scan, the system recognizes only units that are in the same (lo-
cal) network segment as the PC that is running on MOVITOOLS
®
MotionStudio. If
you have units that are outside the local network segment, add the IP addresses of
these units to the list of SMLP servers.
2. Add an IP address by opening the context menu and selecting [Add IP address] [1].
64352AEN
[1] [Add IP address] button
[2] "IP address" edit box