76
Manual – DFE32B Fieldbus Interface PROFINET IO
7
Structure of the PROFINET parameter channel
Parameterization via PROFIdrive Data Set 47
7.2.3 Addressing connected inverters
The structure of the DS47 data set defines an axis element. This element is used to
reach multi-axis drives that are operated via one PROFINET interface. The axis element
addresses one of the units connected via the PROFINET interface.
Addressing a
MOVIDRIVE
®
B
on the PROFINET
With the setting Axis = 0, the parameters of the MOVIDRIVE
®
B drive inverter are ac-
cessed. Since there are no drive units connected to the MOVIDRIVE
®
B, an access with
Axis > 0 is returned with an error code.
62210AXX
Read / Write
Record
Axis = 0
Cyclic OUT Data
Cyclic IN Data
PD
PD
PROFINET
PROFINET
Controller
00
I