Manual – DFE32B Fieldbus Interface PROFINET IO
95
8
Access protection
Integrated Web Server
8.5 Access protection
Access to the drive parameters and diagnostics information can be protected by a pass-
word. Access protection is deactivated by default. You can activate the access protec-
tion function by assigning a password [2]. To deactivate the function again, delete the
password (blank password).
If access protection is activated, a login dialog [1] will appear to request the saved pass-
word.
Under "User" in the login dialog, you can select "Observer" or "Maintenance".
• Observer
– The drive unit parameters can be read with MOVITOOLS
®
MotionStudio but can-
not be not changed.
– The current parameter settings can be uploaded from the unit to the PC (param-
eter set upload).
– It is not possible to download a parameter set or an IPOS
plus®
program.
– Diagnostics via MOVITOOLS
®
MotionStudio is possible, the scope settings, how-
ever, cannot be changed.
• Maintenance
– MOVITOOLS
®
MotionStudio can be operated without any limitations.
61662AXX
[1] Login [2] Config Login
[1]
[2]