56
Manual – DFE32B Fieldbus Interface PROFINET IO
6
MOVIDRIVE® MDX61B – control
Operating Behavior in Conjunction with PROFINET
6.4 MOVIDRIVE
®
 MDX61B – control
The drive inverter is controlled via the process data channel which is up to 10 I/O words
in length. These process data words may be mapped in the I/O or peripheral area of the
controller if a programmable controller is used as IO controller and can be addressed as
usual.
62321AXX
Figure 2: Mapping PROFINET data in the PLC address range
[1] PLC address range
PI1 ... PI10 Process input data
PO1 ... PO10 Process output data
PW156
PW158
PW160
PE 3
PA 3
PE 1
PA 1
PE 2
PA 2
PE 2
PA 2
PE 1
PA 1
PE 3
PA 3
PE 10
PA 10
PW156
PW158
PW160
[1]
MOVIDRIVE
®
 B
INFORMATION
For more information about controlling via the process data channel, in particular re-
garding the coding of the control and status word, refer to the Fieldbus Unit Profile
manual.