Manual – DFE32B Fieldbus Interface PROFINET IO 
119
9
Communication via Ethernet
MOVITOOLS® MotionStudio – Operation
3. Enter the IP address in the input field [2] and click the [OK] button. 
9.9.4 Communication parameters for SMLP
The following table describes the communication parameters for SMLP:
9.9.5 Communication ports used
The following table describes the communication ports used by MOVITOOLS
®
MotionStudio:
Communication parameters Description Note
Timeout Waiting time in ms that the client 
waits for a response from the 
server after it has made a 
request.
• Default setting: 1000 ms
• Increase the value as 
required if a delay in commu-
nication is causing malfunc-
tions.
Broadcast IP address IP address of the local network 
segment within which the unit 
scan is carried out.
In the default setting, the unit 
scan only detects units that are in 
the local network segment.
IP address of SMLP server IP address of the SMLP server or 
of other units that are to be 
included in the unit scan but are 
outside the local network seg-
ment.
• Enter the IP address of units 
that are to be included in the 
unit scan but are outside the 
local network segment.
• Enter the IP address of the 
SIMATIC S7 control, if you 
are operating an indirect 
Ethernet to PROFIBUS com-
munication via SIMATIC S7.
Excluded IP address IP addresses of units that should 
not be included in the unit scan
Enter the IP address of units that 
should not be included in the unit 
scan. This can be units that are 
not ready for communication (for 
example because they have not 
been started up yet)
Use No. of the communica-
tion port
Description
ETH server 300  For using a PC as Ethernet gateway with 
the program "ETHServer.exe"
SEW communication server 301  For communication between 
MOVITOOLS
®
MotionStudio and the 
SEW Communication Server
Offline data server 302 For communication of 
MOVITOOLS
®
MotionStudio in offline 
mode
MOVIVISION
®
 server  303 For communication with a PC with active 
MOVIVISION
®
 server
MOVI-PLC
®
 visualization 304 For communication between MOVI-PLC
®
 
and the 3D simulation of 
MOVITOOLS
®
MotionStudio 
TCI server 305 For communication via TCI
EcEngineeringServer remote 
control (in preparation)
306 For direct communication (without master) 
with SEW EtherCAT slaves
EcEngineeringServer mailbox 
gateway (in preparation)
307 For direct communication (without master) 
with SEW EtherCAT slaves