EasyManua.ls Logo

SEW-Eurodrive DFE32B PROFINET IO - Connection Mode

SEW-Eurodrive DFE32B PROFINET IO
132 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Manual – DFE32B Fieldbus Interface PROFINET IO
99
9
Connection mode
MOVITOOLS® MotionStudio – Operation
9.6 Connection mode
9.6.1 Overview
MOVITOOLS
®
MotionStudio differentiates between "online" and "offline" communica-
tion mode. You can select the communication mode yourself. Depending on the select-
ed communication mode, you can choose offline or online tools specific to your unit.
The following figure illustrates the two types of tools:
12187AXX
[1] Hard drive of the engineering PC
[2] RAM of the engineering PC
[3] Engineering PC
[4] Unit
Tools Description
Offline
tools
Changes made using offline tools affect "ONLY" the RAM [2].
Save your project so that the changes can be stored on the hard disk [1] of your engineer-
ing PC [3].
Perform the "Download (PC->unit)" function if you want to transfer the changes to your
unit [4] as well.
Online
tools
Changes made using online tools affect "ONLY" the unit [4].
Perform the "Upload (unit->PC)" function if you want to transfer the changes to your RAM.
Save your project so that the changes can be stored on the hard disk [1] of your engineer-
ing PC [3].

Table of Contents