Manual – DFE32B Fieldbus Interface PROFINET IO
29
5
Project planning for the PROFINET IO controller
Project Planning with PROFINET
5.1.1 Assigning the PROFINET device name
The general procedure is described using SIMATIC STEP 7 as an example.
• In STEP7 HWCONFIG, select [Target system] / [Ethernet] / [Edit Ethernet node].
• Click on the "Browse" button You receive an overview of all PROFINET IO nodes that
you can reach online with your project planning tool (→ following figure).
• Choose the required node. The SEW node is displayed under device type [3] as
"SEW-MDX61B+DFE32B". The device name [4] is set to "PNETDeviceName" ex
works and must be adapted to your system conditions by you. Several MDX61B units
can be distinguished between by the MAC addresses [2] displayed. The MAC ad-
dress [2] is attached to the DFE32B option. Use the [Flash] button [1] to have status
LED of the selected DFE32B flash green to check your selection.
11727AEN
62340AEN