Operating Instructions – MOVIFIT® basic
7
Operating displays of MB-LC keypad
Operation
7.3 Operating displays of MB-LC keypad
The MB-LC keypad has the following operating displays:
SCAΠ
The MB-LC performs an initialization.
StoP
MOVIFIT
®
basic is ready for normal operation.
The power section of MOVIFIT
®
basic is switched off.
This message is displayed when the drive is at a standstill and no error
is pending.
run
The MOVIFIT
®
basic drive has been enabled by the higher-level con-
troller (drive running)
Lt-C
The MOVIFIT
®
basic drive is in LT control mode (parameter P1-12 ≠
"0", only for MOVIFIT
®
basic inverters).
Controlling the drive is only possible via the LT-BG keypad or the LT
Shell.
bUSY
The MOVIFIT
®
basic drive is inhibited for control via the MB-LC key-
pad.
Reasons:
•The MOVIFIT
®
basic drive has been enabled by the higher-level
controller (drive running)
• Parameter P1-12 ≠ "0".
L-0000
Manual mode has been activated via the key.
The MB-LC keypad controls the MOVIFIT
®
basic drive via control bits
DO3 – DO0.
The digits show the status ("0" or "1") of the current control bits (DO3
CCW, DO0 CW)
triP
An error has occurred.