Operating displays of LT-BG keypad
Operation
7.5 Operating displays of LT-BG keypad
The LT-BG keypad has the following operating displays:
SCAN..
The keypad is scanning the connection to MOVIFIT
®
basic.
Err-SC
Communication error between keypad and MOVIFIT
®
basic.
LOAD..
The keypad is loading the configuration data from MOVIFIT
®
basic.
P-deF
The default parameters (factory setting) are loaded.
StoP
The power section of MOVIFIT
®
basic is switched off.
This message is displayed when the drive is at a standstill and no error
is pending. MOVIFIT
®
basic is ready for normal operation.
P 1 - 0 3
Display of the selected parameter (parameter mode)
5.0
Display of the selected parameter value (setting mode)
H 50.0
Display of the current motor frequency in [Hz]
C 50.0
Display of the display variables P2-22
A 1.2
Display of the actual output current of MOVIFIT
®
basic in [A].
P 0.75
Display of the actual motor power in [kW].
. . . . . .
The actual output current of MOVIFIT
®
basic exceeds the nominal
motor current (parameter P1-08).
Flashing dots
Auto-t
Auto-tune is being performed.
During this process, the motor parameters are measured and
configured.
Enable is not required for starting the auto-tune process.