Operating Instructions – MOVIFIT® basic
71
9
MOVIFIT
®
basic with AS-Interface
Technical data
Brake rectifier BG brake rectifier for SEW brakemotors
Brake voltage = supply voltage V
line
Control input (X21) Connection of the AS-Interface data line via M12 plug connector
Control functions DO0 – DO3, see chapter "Functions of MOVIFIT
®
basic with AS-Interface"
Signaling functions DI0 – DI3, see chapter "Functions of MOVIFIT
®
basic with AS-Interface"
Sensor connections (X22, X23) DI2 binary input sensor 2
DI3 binary input sensor 3
Sensor inputs PLC compatible according to EN 61131-2, sampling time ≤ 8 ms
R
i
about 3.0 kΩ
I
E
about 10 mA
Signal level +15 – +30 V
-3 – +5 V
"1"
"0"
Maximum sensor cable length 15 m
AS-Interface
Protocol variant AS-Interface binary slave with a S-7.F
profile "four bit I/O mode slave"
AS-Interface binary slave with S-
7.A.E profile "4 I/3O AB slave"
AS-Interface profile S-7.F S-7.A.E
I/O configuration 7
hex
7
hex
ID code F
hex
A
hex
ext. ID code 2 E
hex
E
hex
ext. ID code 1 F
hex
7
hex
Address 1 – 31
Factory setting 0
Can be changed as often as required
1A – 31A, 1B – 31B (AB slave)
Factory setting 0
Can be changed as often as required
Power supply to control electronics I
E AS-Interface
≤ 40 mA (typically 25 mA at 30 V)
1) If the unit is stored for a long time, connect it to the supply system voltage for at least 5 minutes every 2 years. Otherwise, the unit's
service life may be reduced.
MOVIFIT
®
basic type MBF07A-K1-A1 MBF15A-K1-A1 MBS4DA-K1-A1 MBS4RA-K1-A1
Part number 1 825 245 1 1 825 248 6 1 825 252 4 1 825 250 8
Inverter
Dual motor
starter
Reversing