MX-M316N SIMULATION 6 – 41
43-10
Purpose
Setting
Function (Purpose)
Used to set the postcard feed cycle
Section
Operation/Procedure
1) Enter the set value with 10-key.
2) Press [OK] key. (The set value is saved.)
43-20
Purpose
Function (Purpose) Used to perform the low-temperature, low-
humidity (L/L) environment correction for
the fusing temperature setting of each
paper (SIM43-01).
Section
Operation/Procedure
1) Select an item to be set with the scroll key.
2) Enter the set value with 10-key.
3) Press [OK] key. (The set value is saved.)
Item Display Content
Setting
range
Default
value
A POSTCARD CYCLE Postcard feed cycle 1 - 99 50
Item Display Content
Setting
range
Default
value
A HL_UM READY LL Correction value for TH_UM set value in ready standby under LL environment 1 - 99 55
B HL_US READY LL Correction value for TH_US set value in ready standby under LL environment 1 - 99 55
C HL_UM PLAIN BW LL Correction value for black and white plain paper TH_UM set value under LL environment 1 - 99 55
D HL_US PLAIN BW LL Correction value for black and white plain paper TH_US set value under LL environment 1 - 99 55
E WARMUP FUMON HL_US T
LL
Correction value for fusing motor previous rotation start TH_UM set value under LL environment 1 - 99 50
F WARMUP FUMOFF LL Fusing motor prior rotation completion time under LL environment 1 - 99 50
G WARMUP END TIME LL Correction value for warm-up complete time under LL environment 1 - 99 50
H HL_UM THIN LL Correction value for thin paper TH_UM set value under LL environment 1 - 99 55
I HL_US THIN LL Correction value for thin paper TH_US set value under LL environment 1 - 99 55
J HL_UM HEAVY LL Correction value for heavy paper TH_UM set value under LL environment 1 - 99 55
K HL_US HEAVY LL Correction value for heavy paper TH_US set value under LL environment 1 - 99 55
L HL_UM LABEL LL Correction value for label paper TH_UM set value under LL environment 1 - 99 55
M HL_US LABEL LL Correction value for label paper TH_US set value under LL environment 1 - 99 55
N HL_UM OHP LL Correction value for OHP-TH_UM set value under LL environment 1 - 99 55
O HL_US OHP LL Correction value for OHP-TH_US set value under LL environment 1 - 99 55
P HL_UM ENV LL Correction value for envelope TH_UM set value under LL environment 1 - 99 55
Q HL_US ENV LL Correction value for envelope TH_US set value under LL environment 1 - 99 55
R HL_UM E-STAR LL Correction value for preheating TH_UM set value under LL environment 1 - 99 55
S HL_US E-STAR LL Correction value for preheating TH_US set value under LL environment 1 - 99 55
T HL_UM PRE-JOB LL Correction value for the set value of TH_UM when restoring from preheating under LL environment 1 - 99 50
U HL_UM WARMUP_120L LL Correction value for TH_UM set value in Warm-Up at 120 degree Cor below under LL environment 1 - 99 55
V HL_US WARMUP_120L LL Correction value for TH_US set value in Warm-Up at 120 degree C or below under LL environment 1 - 99 55
W LO_WARMUP_TIME_LL Correction value for O, P applying time (timer from Ready complete) under LL environment 1 - 99 50
X HL_UM WARMUP_120H LL Correction value for TH_UM set value in Warm-Up at 120 degree C or above under LL environment 1 - 99 55
Y HL_US WARMUP_120H LL Correction value for TH_US set value in Warm-Up at 120 degree C or above under LL environment 1 - 99 55
Z HI_WU_TIME_LL Correction value for R, S applying time (timer from Ready complete) under LL environment 1 - 99 50
AA HI_WU_FM_ON_TMP_LL Correction value for FM prior rotation start TH_UM in Warm-Up at alpha degree C or above under LL
environment
1 - 99 50
AB HI_WU_END_TIME_LL Correction value for Warm-Up completion time in Warm-Up at alpha degree C or above under LL
environment
1 - 99 50
AC HI_WU_JOB_SET_TMP_LL Correction value for Job enable TH_UM temperature (1) when Warm-Up at alpha degree C or above
under LL environment
1 - 99 50
AD HI_WARMUP_BORDER_LL Correction value for the threshold value alpha applying SIM43-1-U - W under LL environment 1 - 99 50
AE LO_WU_JOB_SET_TMP_LL Correction value for Job enable TH_UM temperature (1) when Warm-Up at alpha degree C or below
under LL environment
1 - 99 50
AF JOBEND_FUMON_TIME LL Correction value for the after rotation time when completing a job under LL environment 1 - 99 50
AG HI_WU_JOB_SET_TMP 2
LL
Correction value for Job enable TH_UM temperature (2) when Warm-Up at alpha degree C or above
under LL environment
1 - 99 50
AH LO_WU_JOB_SET_TMP 2
LL
Correction value for Job enable TH_UM temperature (2) when Warm-Up at alpha degree C or below
under LL environment
1 - 99 50