FLOWSIC100 Operating Instructions
Gas Velocity Monitor
Product Description
20 © SICK MAIHAK GmbH · Germany · All rights reserved 8012513/03-2008
The various configuration options are identified by a type key, which is structured as follows:
The possible versions, areas of application, configurations, and characteristics are listed in
the following tables.
Type key for sender/receiver unit: FLSE100-XXX (X) XX XX XX
Purge-air supply yes/no
- P: Purged
Transducer power
- M: Medium power
- H: High power
- S: Low power with small dimensions (Small size)
- PR: Low power with small dimensions and probe version
Signal transmission
- D: Digital
- A: Analog (only FLSE100-SA)
Identification
- empty: No specific characteristics
- AC: Internal cooling of ultrasonic transducers
Nominal length of duct probe
- 12: 125 mm
- 20: 200 mm
- 35: 350 mm
- 55: 550 mm
- 75: 750 mm
Duct probe material
- SS: 1.4571 (Stainless Steel)
- TI: Titanium
- HS: Hastelloy
Transducer material
- TI: Titanium
- HS: Hastelloy
Example: FLSE100-M 35SSTI
medium transducer power
duct probe nominal length 350mm
duct probe material 1.4571
transducer made from titanium