Operating Instructions
GM35
Probe Model
Technical specifications, consumables and spare parts
8009389/07-2006
©
SICK MAIHAK GmbH • Germany · All rights reserved
103
10.2.5
Dimensions GM35 Evaluation Unit, casting housing
Fig. 49
Dimensional drawing of the GM35 evaluation unit, casting housing model
9
438
440
Table of Contents
Table of Contents
7
Important Information
10
Main Hazards
11
Hazards from Hot And/Or Aggressive Gases And/Or High Pressure
11
Hazards through Electrical Equipment
11
Intended Use
12
Responsibility of User
13
General Information
13
Safety Information and Protective Measures
13
Product Description
16
Measuring Principle, Measured Variables
17
Functional Principle
17
Response Time
18
Function Check
19
Device Components
22
Sender/Receiver Unit
23
Reflector
25
Flange with Tube
26
MCU Control Unit
26
Optional External Purge Air Unit
31
Installation Accessories
31
Device Check Accessories
32
Device Features and Configuration
33
Device Features
33
Device Configuration
34
Assembly and Installation
36
Project Planning
37
Assembly
38
Fitting the Flange with Tube
38
Fitting the MCU Control Unit
41
Fitting the Optional External Purge Air Unit
43
Fitting the Weatherproof Cover
44
Installation
45
General Information, Prerequisites
45
Connecting/Starting the Optional External Purge Air Unit
45
Installing the Purge Air Supply
47
Connecting the MCU Control Unit
48
Connecting the Reflector on DUSTHUNTER T200
51
Fitting and Connecting Optional Interface and I/O Modules
51
Start-Up and Parameter Settings
52
Basics
53
General Information
53
Installing the Operating and Parameter Program SOPAS et
53
Connecting to the Device
55
Information on Using the Program
58
Online Help
59
Troubleshooting/Technical Specifications, Consumables and Spare Parts
341
Check and Adjust the Optical Alignment of des GM35
408
Electrical Connections
408
Insertion in the Measuring Gas Duct
408
Resuming Measuring Mode
408
Completing Maintenance Work at the Measuring Point
409
Evaluation Unit
410
Carrying out the Measurement
411
Determining the Required Test Gas Concentration
411
Filter Box Measurement for Checking the Gas Ducts of CO and CO (up to 15 Vol.% X M)
411
Carrying out the Measurement
414
Resuming Measuring Mode
414
Set Values
414
Resuming Measuring Mode
416
Integrated Monitoring and Diagnosis System
417
Malfunction Categories/Possible Effects
417
Purge Air Failure
417
Troubleshooting
417
Error Messages for the GM35 SR Unit
419
Troubleshooting the Evaluation Unit
419
Warning Messages for the GM35 SR Unit
428
Further Tips on Troubleshooting
429
Measuring Components and Accuracy
431
Technical Specifications, Consumables and Spare Parts
431
GM35 System Components
432
Stability
432
Dimensioned Drawings
435
GM35 SR Unit
435
With GMP Measuring Probe
436
GPP Measuring Probes
437
Dimensions GM35 Evaluation Unit, Steelplate Housing
438
Dimensions GM35 Evaluation Unit, Casting Housing
439
Purge-Air Unit SLV 4
440
Weatherproof Covers
440
Dimensioned Drawing and Version Table for the Flange with Tube
442
Terminal Box for CAN Bus Connection
442
Consumables and Spare Parts
443
Consumables for 2-Year Operation
443
Spare Parts of the SR Unit
443
Spare Parts of the Measuring Probe
445
Spare Parts of the Evaluation Unit
447
Securing Material
448
Spare Parts for Purge-Air Unit
448
Spare Parts Mmscellaneous
448
Table of Contents
459
System Description
460
Configuration
464
Function
464
System Operation
464
Equipment Standard
467
Display
469
Appendix
503
Communication Cable Connection
503
D/L Expediency
503
Digital I/O Connection Method
503
Measuring Item and Unit Change
503
Multi-Port
503
Probe Purge Timing Diagram
503
Replace ROM of D/L
503
Table of D/L Checkup
503
User Manual
533
Dahs
534
Introduction
534
Software Specipication
535
System Requirements
535
Nstall Dahs
537
Usb Keylock Setup
539
General
540
Station / Item
541
Basic Item
544
Com Port
545
Execute Software
546
Menu
546
Main Screen
547
View Data
548
View Comm
549
Dump Data ( Retransmission )
550
4
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the SICK DUSTHUNTER T and is the answer not in the manual?
Ask a question
SICK DUSTHUNTER T Specifications
General
Brand
SICK
Model
DUSTHUNTER T
Category
Measuring Instruments
Language
English
Related product manuals
SICK DUSTHUNTER T50
261 pages
SICK DUSTHUNTER T100
261 pages
SICK DL100
144 pages
SICK DL100 Pro
126 pages
SICK GM32
80 pages
SICK Lector85x
50 pages
SICK MLG-2 Pro
138 pages
SICK FLOWSIC600
100 pages
SICK FLOWSIC500
176 pages
SICK FLOWSIC100
184 pages
SICK FLOWSIC600-XT
164 pages
SICK MLG-2 WebChecker
132 pages