FLOWSIC100 Operating Instructions
Gas Velocity Monitor
Product Description
22 © SICK MAIHAK GmbH · Germany · All rights reserved 8012513/03-2008
Application range
1): The maximum possible measuring distance depends on the dust content, gas temperature, and
gas composition
2): for extremely high dust concentrations up to max. 100 g/m³
3): for installation across secant (see Section
3.1.3)
Configuration options
Type
FLSE100
Probe
material
Transducer
material
Max. gas
temperature
[°C]
Active meas.
distance
1)
[m]
Duct/pipe
diameter
[m]
M
SS, TI TI
260
0.2 - 4 0.15 - 3.4
Hastelloy 0.2 - 2 0.15 - 1.7
H
SS, TI TI
2 - 15 1.4 - 13
1.5 - 2.5
2)
1.1 - 2.5
3)
Hastelloy 2 - 5 1.4 - 4.3
PR SS, TI
Tl
0.27 - 0.28 > 0.40
SA/SD SS 150 0.2 - 2 0.15 - 1.7
MAC
SS, TI
450
0.2 - 4 0.15 - 3.4
HAC
2 - 13 1.4 - 11.3
1.5 - 2.5
2)
1.1 - 2.5
3)
PRAC 350 0.245 - 0.255 > 0.40
PM SS
450
0.5 - 3 0.35 - 2.5
PH SS, TI
1 - 10 0.7 - 8.7
1 - 2
2)
0.7 - 2
3)
PHS SS
2 - 13 1.4 - 11.3
1.5 - 2.5
2)
1.1 - 2.5
3)
Type FLSE100 Duct probe
Nominal length in mm Material
125 200 350 550 750 SS TI HS
M xxx xxx
H xxxxxxx
PR xxxxx
SA/SD x
xx
x
MAC x x x x
HAC x x x x
PRAC xxxx
PM xxxxx
PH xxxxxx
PHS xxxx

Table of Contents