Operating Instructions FLOWSIC100
Gas Velocity Monitor
Product Description
8012513/03-2008 © SICK MAIHAK GmbH · Germany · All rights reserved 45
1)
: The accuracy of flow measurements depends on calibration, installation situation, the flow profile, and the variation range of the
pressure and temperature parameters. Typical values for the single-path measurement are 1 … 5 %.
2)
: The maximum possible measuring distance depends on the dust content, gas temperature, and gas composition.
3)
: Maximum measuring distance FLSE100-M HSHS (duct probe and transducer in hastelloy) 2 m.
4)
: Maximum measuring distance FLSE100-H HSHS (duct probe and transducer in hastelloy) 5 m.
5)
: Minimum diameter for installation angle 45°, maximum diameter for installation angle 60°.
6
): With high dust concentrations installation angle 60°.
7)
: With standard purge-air unit.
8
): With purge-air fan 2BH1400 at overpressure of > 0.03 bar (contact SICK MAIHAK).
9)
: The maximum possible dust concentration depends on the measuring distance and the gas temperature.
10)
: Only for dry and non-sticky dust.
11)
: Lower ambient temperatures for FLSE and MCU on request.
13)
: For the MCU with integrated purge-air unit, the ambient temperatures may not sink below -40 °C during operation and -20 °C
during start up operation of the fan.
Ambient conditions
Temperature range
11)
-40 ... +60 °C
-40 ... +60 °C
-40 ... +45 °C
Sender/receiver units:
Control unit MCU-N:
Control unit MCU-P, purge-air supply in connection box
13)
Storage temperature –40 ... +70 °C
Degree of protection IP 65
Dimensions, mass
FLSE100 Nominal length (type specific) 200 / 260 / 350 / 550 / 750 mm;
Max. mass (type specific) max. approx. 10.6 kg
MCU-N Dimensions: 340 x 210 x 120 mm; steel plate housing, coated
Mass: approx. 5 kg
MCU-P, purge-air supply in
connection box
Dimensions: 440 x 300 x 220 mm; steel plate housing, coated
Mass: approx. 14 kg
Flange with pipe Nominal length 125 / 200 / 350 / 550 / 750 mm;
Pitch diameter of the mounting holes 75 / 100 / 170 mm (depends on FLSE100 type);
Material St37, V4A (others on request), max. mass approx. 6 kg
Option purge-air unit (with fan type 2BH1300)
Components Mounting plate, air filter, purge-air fan, Y distributor, low-pressure monitor
Operating voltage 200 ... 240 V / 345 ...415 V at 50 Hz; 220 ... 275 V / 380 ...480 V at 60 Hz
Rated current Δ 2.6 A / Y 1.5 A
Motor rating 0.37 kW at 50 Hz; 0.45 kW at 60 Hz
Delivery rate
max. 63 m
3
/h; 48 m
3
/h at back-pressure of 30 mbar
Ambient temperature –20 ... +40 °C
Degree of protection IP 54
Hose connections Ø 40 mm
Dimensions 550 x 550 x 270 mm; mass 14 kg