94
8012428/YWL2/3-0/2016-08| SICKO P E R A T I N G I N S T R U C T I O N S | DUSTHUNTER T
Subject to change without notice
5 MAINTENANCE
Maintenance intervals
The equipment operator must specify the maintenance intervals. The period depends on
existing operating parameters such as dust content and state, gas temperature, how the
equipment is run and ambient conditions. Therefore only general recommendations can be
made here. Normally, the maintenance intervals are about 4 weeks during the initial period
and can be steadily incremented to up to a year depending on the respective conditions.
The equipment operator must specify the specific work to be carried out and its perfor-
mance in a Maintenance Manual.
Maintenance contract
Scheduled maintenance work can be carried out by the equipment operator. Only qualified
personnel according to Section 1 should be allowed to do the work. If requested, all mainte-
nance activities can also be performed by SICK Service or an authorized Service partner.
Any repairs will be made by specialists onsite whenever possible.
Auxiliary means required
Brush, cleaning cloth, cotton swabs
Water
Replacement air filter, preliminary filter (for suction)

Table of Contents