9 TECHNICAL DATA
8011325/18IM/2020-07-02|SICK
OPERATING INSTRUCTIONS | ICR880/890
Subject to change without notice
9.3 Data sheet for ICI890-2x / ICI890-3x / ICI890-4x illumination unit
Type
ICI890-23xxx
ICI890-33xxx
ICI890-43xxx
ICI890-24xxx
ICI890-34xxx
ICI890-44xxx
ICI890-25xxx
ICI890-35xxx
ICI890-2x: red, λ = 630 nm
ICI890-3x: white, λ = 400 nm to 750 nm
ICI890-4x: blue, λ = 449 nm
Risk group RG 1 (low risk) according to IEC 62471-1: 2006-07 / EN 62471-1: 2008-09.
Irradiance: L
B
< 10 x 10
3
W/(m²sr)
within 100 s (RG 1),
at distances ≥ 200 mm.
L
R
< 2.8 x 10
5
W/(m²)
within 10 s (RG 0),
at distances ≥ 200 mm.
Variants with white and blue LEDs
Risk group RG 2 (moderate risk) acc. to IEC 62471-1: 2006-07 / EN 62471-1: 2008-09
due to blue light hazard.
Irradiance: L
B
< 4 x 10
6
W/(m²sr)
within 0.25 s (RG 2),
at distances ≥ 200 mm.
L
R
< 2.0 E6 W/(m²sr)
within 0.25 s (RG 2),
at distances ≥ 200 mm.
Risk RG 1 (low risk) corresponding to L
B
< 10 x 10
3
W/(m²sr) within 100 s at distances
> 10 m. This distance is only necessary in the range of maximum brightness in the direct
Depending on reading pulse, minimum switch-off time 3 s
1 x male connector, M12, 8-pin (control data interface for the camera)
1 x Harting HanQ8 plug connector, 8-pin (input for DC 24 V voltage supply)
ICI890-xxx1x
1 x male connector, M12, 8-pin (control data interface for the camera)
1 x male connector, M12, 5-pin (input for DC 24 V voltage supply)
3)
3)
3)
Aluminum die cast/plastic (glass for camera view)
Outside of the housing, no materials using silicon
IP 64 according to EN 60529: 1991-10; A1: 2000, A2:2013, fan IP 54
Class III in accordance with EN 61140: 2016
In accordance with EN 61000-6-2: 2005, EN 61000-6-4: 2007
In accordance with IEC 60068-2-6: 2007
In accordance with IEC 68-2-27: 2008-02, equivalent to EN 60068-2-27: 2009