5 ELECTRICAL INSTALLATION
8011325/18IM/2020-07-02|SICK
OPERATING INSTRUCTIONS | ICR880/890
Subject to change without notice
Image data output for OCR
Tab. 14: Camera – ICD890-xxxxxxxS03 electrical connections
5.2.2 Electrical connections on the ICI890 illumination unit
The ICI890-xxx0x illumination unit features a Harting HanQ plug connector for the voltage
supply and a M12 plug connector for the control cable. Connect the camera and
illumination unit via the cables pre-installed within the illumination unit.
The ICI890-xxx1x illumination unit comes with an M12 plug connector for the voltage
supply and the control cable. Connect the M12 connection of the ICI890-xxx1x
illumination to the Harting HanQ connection of the camera via an adapter (part number:
2098253).
Fig. 39: Illumination unit – electrical connections
The following interfaces are controlled via the connections on the ICI890-xxx0x
illumination unit:
Control data interface for the camera
Input for DC 24 V voltage supply
Tab. 15: Illumination unit ICI890-xxx0x – electrical connections
The following interfaces are controlled via the connections on the ICI890-xxx1x
illumination unit:
Control data interface for the camera
Input for DC 24 V voltage supply
Tab. 16: Illumination unit ICI890-xxx1x - electrical connections
5.2.3 Pre-wired cables (overview)
Interface from
camera to
Cable part
no.
Carried out by Length
Enclosure
rating
(RS-232,
TPU/PUR outer sheath
connector