TROUBLESHOOTING 8
93
8011325/18IM/2020-07-02|SICK
OPERATING INSTRUCTIONS | ICR880/890
8 Troubleshooting
This chapter describes how to identify and rectify faults on the camera system.
8.1 Overview of potential errors and faults
8.1.1 Errors during mounting
1. Camera system poorly aligned to objects with 1D/2D codes (e.g., dazzle)
2. Read-cycle sensor incorrectly positioned (e.g., internal reading gate is opened too late
or closed too early)
3. Focus position switching: sensors for detecting the respective object height incorrectly
positioned
4. Incremental encoder (optional) incorrectly positioned
8.1.2 Error during electrical installation
Interfaces of the camera system incorrectly wired
8.1.3 Errors during configuration
Functions not adapted to local conditions, e.g., parameters for the data interface not
set correctly
Device limits not observed, e.g., reading distance, aperture angle
Trigger source for read-cycle not selected correctly
8.1.4 Faults during operation
Tracking operation: minimum distance of the objects in the conveying direction not met
Time-out period of the illumination unit exceeded
Device faults (hardware/software)
8.2 Detailed fault analysis
8.2.1 LEDs on the camera
A number of statuses can be read from the LEDs by the electrical connections of the
camera (see chapter 3.6.2 Camera LEDs), including the following:
Result of the self-test
Operational status
Fulfillment of a configured condition (e.g., display of Good Read)
Maintenance or service activity required
The LED display can indicate possible errors or faults.
Further information on this can be found in the “System information” section.