MOUNTING 4
45
8011325/18IM/2020-07-02|SICK
OPERATING INSTRUCTIONS | ICR880/890
Inserting the camera
1. Remove the protective cap on the illumination unit.
2. Ensure that the sealing ring on the illumination unit is sitting correctly (1).
3. Remove the yellow protective cap on the camera (2).
Fig. 32: Mounting the camera system: inserting the camera
4. Attach the camera to the illumination unit on the correct side and carefully insert the
object protection tube into the opening of the illumination unit.
5. Fix the screw in the fitting (round hole).
Fig. 33: Mounting the camera system: inserting the screw into the fitting
6. Screw the camera onto the illumination unit with the four hexagon socket screws
(centering pin with thread).
Aligning the camera system
1. Loosen the clamping screws on the 180° mounting brackets.
2. Horizontally align the unit consisting of the illumination unit and the camera to an angle
of 0°, i.e., parallel to the conveyor.
3. Tighten the clamping screws.