9 TECHNICAL DATA
8011325/18IM/2020-07-02|SICK
OPERATING INSTRUCTIONS | ICR880/890
Subject to change without notice
9 Technical data
9.1 Data sheet for ICD880/ICD890 camera
Type ICD880-32121xx
ICD890-32001xx
ICD890-32011xx
ICD890-33001xx
ICD890-33011xx
1)
Line camera with 8,192 pixels
Line frequency (scanning rate)
distance of 0.8 m
190 dpi with a reading
250 dpi with a reading distance of 2 m
170 dpi with a reading distance of 3 m
Max. 36° up to reading
distance of 1.05 m
Max. 25° up to reading distance of 2.4 m
Cover for width of conveyor in
conveyor system
of 250 dpi
800 mm with a resolution
1,000 mm with a resolution of 170 dpi
600 mm with a resolution of 250 dpi
of 200 dpi
250 mm with a resolution
1,600 mm with a resolution of 170 dpi
600 mm with a resolution of 250 dpi
1.4 m ... 3 m
1.6 m ... 3.3 m
Max. conveyor speed (objects)
2.4 m/s with a resolution of 200 lpi
3.2 m/s with a resolution of 150 lpi
3.8 m/s with a resolution
of 200 lpi
5.1 m/s with a resolution
Supported lenses (standard)
1D code types (bar codes)
2/5 interleaved, Code 39, Code 128, EAN/UPC with add-on, Codabar, EAN 128
Data Matrix ECC200, PDF417, MaxiCode, QR code, Aztec (optional)
Number of objects per second
Number of codes per object
Number of characters per 1D code
Max. 50 characters (max. 1,000 characters across all 1D codes per reading gate)
Number of characters per 2D code
Number of multi-reads (1D code)
Memory card for parameters (cloning)
5 x LEDs (status indicators)
Tab. 34: Technical specifications for the ICD880/ICD890 camera