Loading...
COMMISSIONING AND CONFIGURATION 6
75
8011325/18IM/2020-07-02|SICK
OPERATING INSTRUCTIONS | ICR880/890
6.3 Configuring the camera system in SOPAS-ET
Now open the SOPAS-ET configuration interface.
To do so, double-click on the tile in the project tree.
All configurable parameters of the camera system are compiled together in a
corresponding device description for the SOPAS-ET configuration software. The project
tree of the device description is used as an aid for configuration.
6.3.1 Logging into the device
To be able to access all of the camera system's parameters in the SOPAS-ET configuration
software, you must log into the device using the Service user level.
After the first start-up, the configuration software works with the Maintenance Technician
user level (= operator level).
1. Select the Device Login command in the menu bar.
2. In the Login dialog window, select the Authorized Client user level and enter the
default password client.
3. Click Login to confirm your entry.
The parameters that were previously shown grayed out in the windows are now
accessible.