PRODUCT DESCRIPTION 3
33
8011325/18IM/2020-07-02|SICK
OPERATING INSTRUCTIONS | ICR880/890
3.4.10 Data interfaces
The following data interfaces are available on the camera system:
Interface
Connection
Function
CAN bus
CAN 1 (out/in)
Networking of one or more camera systems with the
controller unit
Ethernet
(alternative to
controller unit)
HOST ETHERNET
(not for ICD890-
xxxxxxxS03)
Output of the read result of the AUX interface
(AUX port)
Configuration/read diagnostics with SOPAS-ET
configuration software
Output of the read result of the host interface
(host port)
Serial auxiliary
interface
(alternative)
AUX (RS-232)
Configuration/read diagnostics.
Not designed as a permanent data output interface
(process interface) for the read result.
PC Ethernet
GBIT ETHERNET
Provision of image data of current read for further
processing
Tab. 8: Function of data interfaces
3.5 Configuration with SOPAS-ET
The SOPAS-ET configuration software can be used to configure the operating principle of
the camera system in line with the customer requirements.
The software is installed on a PC, which is generally connected to the camera system via
the controller by means of Ethernet.
You can define various settings, including:
Configuration of the code position and the symbol contrast.
Configuration of the image resolution perpendicular to the conveyor direction (digital
zoom in dpi) and in the conveyor direction (dynamic scanning frequency in lpi).
Configuration of the trigger source.
Configuration of the camera focusing (default position and source of the distance
measurement).
Configuration of the illumination mode and time-out for the illumination unit.
Configuration of the position and inclination angle of the camera and the deflector
mirror.
Configuration of the increment source and the resolution/speed.
Configuration of the image format and the scaling/quality.
Configuration of the code types for 1D and 2D codes.
Configuration of the network parameters.
Configuration of the data interfaces.
You can learn how to connect to SOPAS-ET and configure the camera system in chapter
6 Commissioning and configuration).