MAINTENANCE AND CARE 7
83
8011325/18IM/2020-07-02|SICK
OPERATING INSTRUCTIONS | ICR880/890
Removing grease deposits
1. Spray the affected areas with conventional glass cleaner.
2. Carefully wipe paper tissue (recommendation: “Kleenex”) over the affected area. Only
apply light pressure to the mirror. Do not scour!
3. Let the mirror dry. Do not wipe the mirror dry!
NOTE
Cleaning the deflector mirror mounted underneath the conveyor
The deflector mirror mounted underneath the conveyor features a chrome coating.
Due to its high abrasion and scratch resistance, this coating can be cleaned more
frequently.
7.1.4 Maintaining the cleaning unit fan
Clean the surface of the fan housing on a regular basis.
Changing the air filter mat
Change the air filter mat in accordance with the respective maintenance interval.
Fig. 50: Changing the air filter mat in the cleaning unit
1. Loosen the wing nut.
2. Remove the air filter mesh.
3. Remove the air filter mat and replace it.
4. Mount the air mesh and tighten the wing bolt.