Mounting new deflector mirror
1. Insert the new deflector mirror into the 180° mounting bracket.
2. Fasten the deflector mirror onto the bracket with the two fixing screws.
3. Loosen the clamping screws and re-position the deflector mirror such that it is in its
original location.
4. Firmly re-tighten the clamping screws.
5. Remove the protective foil on the new deflector mirror.
Checking alignment
1. Reconnect the voltage supply.
2. Switch on the illumination unit of the camera.
3. Check whether the deflector mirror is correctly aligned.
You can also remove the deflector mirror without changing the angle of the two 18
mounting brackets.
When removing the fixing screws, the deflector mirror must be held and protected against
falling by a second person.
7.2.1.3 Replacing the deflector mirror underneath the conveyor
The deflector mirror mounted underneath the conveying surface can easily be replaced
due to the separation of the base support and mirror holder. The deflector mirror is
secured on both sides via an arm on the base support.
Fig. 60: Replacing the deflector mirror (underneath the conveyor) – components
No.
Meaning
1
Base support
2
Mirror holder
3
Arm