9 TECHNICAL DATA
102
8011325/18IM/2020-07-02|SICK
OPERATING INSTRUCTIONS | ICR880/890
Subject to change without notice
9.5 Specifications diagrams
9.5.1 Reading conditions for diagrams
Test code
Code 128
Code quality
A or B, in accordance with ANSI
Print contrast
> 90%
Ambient light
< 2,000 lx
Tilt/pitch/skew
360° / 15° ... +15° / 15° ... +15°
Tab. 39: Reading conditions for specifications programs
9.5.2 Read ranges of the camera systems
Camera system 1: ICD880 camera with ICI890-x1xxx / ICI890-x4xxx illumination unit
(profile length: 900 mm)
Fig. 64: Reading ranges of the camera system 1: ICD880 camera with ICI890-x1xxx / ICI890-
x4xxx illumination unit
The ICD880 camera with ICI890-x2xxx / ICI890-x5xxx illumination unit (profile length:
750 mm) reaches a reading field height of ±300 mm and therefore covers a conveyor
track width of 600 mm.
Note