8. If you selected Yes, select Gateway address:
a. Enter the gateway address.
The header displays the numbers entered and adds the stop characters
in the correct positions.
b. Select
Enter.
The correct Mac address displays on the screen.
9. To return to the first Network settings menu, select
Previous Screen.
10. Select
Previous Screen.
Barcode Reader Options
If you are using the optional handheld barcode reader, use this procedure to
set parameters based on the barcoded labels being used.
1. Select Bar Code reader options.
2. Ensure that the barcode label is readable:
a. Select
Test bar code.
The message Scan bar code label displays.
b. Scan a label that is representative of the quality and size being used
and for which you know the expected results.
c. Verify that the information on the screen is correct.
d. Compare the displayed result with the known value of the label and
determine if any characters need to be ignored.
The handheld barcode reader can read a barcode that contains up to
30 characters, however, a maximum of 13 characters displayed, stored,
and transmitted by the analyzer. All characters in excess of 13 must be
ignored, up to a maximum of 18. You can have the analyzer ignore
characters at the beginning or end of the barcode, or a combination of
both.
e. Select
Previous Screen.
NOTE: You may want to test more than 1 label, especially if they are
printed from different sources. If you use more than 1 format, test at least 1
label from each format. Refer to Appendix F, Barcode Reader.
3. Use the Leading char. to ignore cycle key to ignore between 0 and 9
characters at the beginning of the barcode.
4. Use the Trailing char. to ignore cycle key to ignore between 0 and 9
characters at the end of the barcode.
5. Select
Previous Screen.

Table of Contents

Other manuals for Siemens Clinitek Advantus

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Clinitek Advantus and is the answer not in the manual?

Siemens Clinitek Advantus Specifications

General IconGeneral
Test TypesUrinalysis
InterfaceRS-232, USB
CalibrationAutomatic calibration
Measurement PrincipleReflectance photometry
Sample TypeUrine
Power Supply100-240 VAC, 50/60 Hz
TypeUrine analyzer
DisplayTouchscreen
Reagent TypeTest strips
Measurement ParametersGlucose, Bilirubin, Ketone, Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite, Leukocytes

Related product manuals