94 RM400 C Models U24802-J-Z146-2-7600
7
Software
Example of how to configure the graphical monitor under Reliant UNIX:
A menu containing three items is displayed: Hardware, Startup and Extended. Each of
these menu items displays a submenu. You must configure the hardware, but you
can accept the default settings for the other two parameters.
submenu Hardware
Information on the parameters:
Graphics Hardware If you have not installed an additional graphics controller,
select an onboard graphics controller (Cirrus Alpine). If you
have installed an additional graphics controller, select an
onboard graphics controller of the type Millinenium.
Press the
[CHOICES] function key and select a module.
Cirrus Alpine PCI 2 MB (CL-GD 5436)
SNI MCM 1502 35 cm color (K323-V3xx)
800x600, 8 bits/pixel, 120.2Hz