Data blocks / error lists
C.4 Error classes
FM 352 electronic cam controller
192 Operating Instructions, 05/2011, A5E01071724-03
No. Meaning Diagnostic
interrupt
Incorrect actual value specified by "set actual value" / "set actual value on-the-
fly"
35
Cause The specified actual value is outside the permitted numeric
range of ±100 m or ±1000 m.
When this setting is applied, the software limit switches would
be outside the traversing range
(-100 m to +100 m or -1000 m to +1000 m).
The offset derived from set actual value / set actual value on-
the-fly would be more than ±100 m or ±1000 m.
No
Axis parameters not assigned 107
Cause There are no machine data on the axis.
There are no machine data activated on the axis.
No
Axis not synchronized 108
Cause One of the settings "set actual value" or "set actual value on-
the-fly" was initiated although the axis is not synchronized.
No
109 Cam processing running. No
110 Incorrect number of cams to be modified No
Class 5: Machine data error
The diagnostic interrupt is only triggered if an error is detected in the system data block
(SDB).
No. Meaning Diagnostic
interrupt
Error in hardware interrupt setting 5
Cause You have attempted to select a hardware interrupt that the
module does not support.
Yes
Incorrect minimum edge distance 6
Cause You have entered a value <0 or >10
9
µm as the minimum edge
distance
Yes
Incorrect axis type 8
Cause You have specified neither 0 nor 1 as the axis type
Yes
Incorrect end of rotary axis 9
Cause The value for the end of rotary axis is outside the permitted
range of 1 to 10
9
µm or 1 to 10
8
µm (depending on the
resolution).
Yes
Incorrect encoder type 10
Cause The value for the encoder type is outside the permitted range
of 1 to 10
Yes