Siemens SIMATIC ET 200SP Operating Instructions

Siemens SIMATIC ET 200SP
166 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
6.5.29 SecureDisplay version [secureDisplayVersion]......................................................................70
6.5.30 Smallest zoom factor of SecureDisplay (%) [smallestZoomFactorOfSecureDisplay] ............70
6.6 DR04 Calibration curve check................................................................................................70
6.7 DR05 Tare and zero memory.................................................................................................70
6.8 DR06 Configuration of limits ..................................................................................................71
6.8.1 Reference (limits 1 and 2) [limitReference] ............................................................................71
6.8.2 Limit 3 - empty [emptyLimit] ...................................................................................................71
6.8.3 Switch-on delay limit 3 (empty) (s) [delayTimeForEmptyLimit] ..............................................72
6.9 DR07 Interface parameters....................................................................................................72
6.9.1 Assignment DI.0, DI.1, DI.2, CI [functionDI0 to functionDI2] [functionCI] ..............................72
6.9.2 Filtering DI.0, DI.1, DI.2 and CI ..............................................................................................73
6.9.3 Assignment DQ.0, DQ.1, DQ.2 ..............................................................................................73
6.9.4 Reaction to CPU stop / failure [behaviourOnCPUStopOrFailure] ..........................................73
6.9.5 Monitoring of digital outputs [monitoringOfDQ] ......................................................................74
6.9.6 Reaction of digital outputs to a CPU stop / failure [behaviourOfDQOnCPUStopOrFailure]......74
6.9.7 Behavior of digital outputs on error [behaviourOfDQOnError] ...............................................74
6.9.8 Substitute value for DQ.0 to DQ.3 on error ............................................................................74
6.9.9 Trace rate [traceRate] ............................................................................................................75
6.9.10 Subnet mask, IP address, gateway, device name .................................................................75
6.9.11 Activate Modbus communication [activateModbusConnection1]
[activateModbusConnection2]................................................................................................75
6.9.12 Modbus TCP Unit Identifier, port, SWAP options...................................................................76
6.9.13 Byte/Word swap options [byteSwap16Bit] [byteSwap32Bit] [wordSwap32Bit] ......................76
6.9.14 RS485 protocol ......................................................................................................................76
6.9.15 I/O process values 1 to 4 [ioProcessValue1 to ioProcessValue4] .........................................76
6.9.16 I/O process values 5 to 8 [ioProcessValue5 to ioProcessValue8] .........................................77
6.9.17 Event hardware interrupts 4 to 8 [hardwareInterrupt4 to hardwareInterrupt8] .......................78
6.9.18 Source for weight simulation [simulationSource] ...................................................................78
6.10 DR09 Read out module information.......................................................................................78
6.11 DR10 Load cell parameters ...................................................................................................78
6.11.1 Load cell type [loadCellType] .................................................................................................78
6.11.2 Connection technology [fourSixWireSensor]..........................................................................79
6.11.3 Load cell manufacturer [loadCellManufacturer] and load cell order number
[loadCellOrderNumber] ..........................................................................................................79
6.11.4 No. of mechanical support points [numberOfSupportPoints] .................................................79
6.11.5 Averaged load cell characteristic (mV/V) [averagedCharacteristicValue] ..............................79
6.11.6 Nominal load of one single load cell [nominalLoadOfSingleLoadCell] ...................................79
6.11.7 Power line frequency [powerLineFrequency] .........................................................................80
6.11.8 Using a power line filter [PowerLineFilterActivated] ...............................................................80
6.11.9 External / internal sensor supply [internalExternalAdcSupply]...............................................80
6.11.10 Impedance .............................................................................................................................80
6.12 DR15 Preset tare ...................................................................................................................80
6.13 DR16 Configuration of weight simulation ...............................................................................81
6.13.1 Simulate weight......................................................................................................................81
6.13.2 Simulating dosing...................................................................................................................82
6.13.3 Material flow, delay time and opening/closing time................................................................83
6.14 DR18 Digital output and transition control..............................................................................84
6.14.1 Controlling digital outputs.......................................................................................................84
Table of contents
Technology module TM SIWAREX WP351 HF
Operating Instructions, 01/2020, A5E47521010-AA 5

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C