6.14.2 Enabling transitions................................................................................................................85
6.15 DR20 Configuration of set point [setPoint] .............................................................................86
6.16 DR21 Configuration of total set point [totalSetPoint]..............................................................86
6.16.1 DR21 Configuration of total set point in DTI...........................................................................86
6.16.2 DR21 Configuration of total set point GFI ..............................................................................87
6.17 DR22 Tolerance parameters..................................................................................................88
6.17.1 Overview ................................................................................................................................88
6.17.2 Parameter relation [parameterRelation] .................................................................................88
6.17.3 Tolerance limit TH2 (weight unit) [toleranceLimitTh2]............................................................88
6.17.4 Tolerance limit TH1 (weight unit) [toleranceLimitTh1]............................................................89
6.17.5 Tolerance limit TL1 (weight unit) [toleranceLimitTl1]..............................................................89
6.17.6 Tolerance limit TL2 (weight unit) [toleranceLimitTl2]..............................................................89
6.17.7 Behavior in case of TH1 error [behaviorTh1Violated] ............................................................89
6.17.8 Behavior in case of TL1 error [behaviorTl1Violated] ..............................................................89
6.17.9 Pulse duration for pulse post dosing (s) [pulseDuration]........................................................90
6.17.10 Number of unchecked weighing cycles [cyclesWithoutCheck] ..............................................90
6.17.11 Capture of weighings into statistics [statisticsData] ...............................................................91
6.18 DR23 Material parameters .....................................................................................................91
6.18.1 Parameter relation [parameterRelation] .................................................................................91
6.18.2 Fine weight [fineWeight].........................................................................................................91
6.18.3 Trailing weight fine [trailingWeightFine] .................................................................................92
6.18.4 Coarse weight [coarseWeight] ...............................................................................................93
6.18.5 Trailing weight coarse [trailingWeightCoarse]........................................................................93
6.18.6 Trailing weight extra coarse [trailingWeightXCoarse] ............................................................93
6.18.7 Blocking time extra coarse (s) [blockingTimeXCoarse]..........................................................93
6.18.8 Blocking time coarse signal (s) [blockingTimeCoarse]...........................................................94
6.18.9 Blocking time fine signal (s) [blockingTimeFine] ....................................................................94
6.18.10 Blocking time discharging (s) [blockingTimeDischarge].........................................................94
6.18.11 External triggered blocking time (s) [externalBlockingTime] ..................................................94
6.18.12 Shut-off correction weight [shutOffCorrectionWeight] ............................................................94
6.18.13 Minimum material flow (weight/s) [minimumMaterialFlowRate] .............................................95
6.19 DR24 Controller parameters ..................................................................................................95
6.19.1 Parameter relation [parameterRelation] .................................................................................95
6.19.2 Type of controller [controllerType]..........................................................................................95
6.19.3 Control factor of proportional controller (%) [controlFactorPController] .................................96
6.19.4 Control factor of fine time controller (%) [controlFactorTController].......................................96
6.19.5 Max. control access of proportional controller [maximumControllAccessPController] ...........96
6.19.6 Proportional controller deadband - upper limit [deadBandPControllerPlus]...........................96
6.19.7 Proportional controller deadband - lower limit [deadBandPControllerMinus].........................97
6.19.8 Controller behavior in case of exceeding max. control access [controllerErrorBehavior] ......97
6.19.9 Intervention of fine time controller [interventionTController]...................................................97
6.19.10 Set point fine time controller (s) [setPointTController]............................................................97
6.19.11 Adopt corrected fine-/trailing values to DR23 automatically [adoptCorrectedValues]............98
6.19.12 Max. control access of fine time controller [maximumControllAccessTController].................98
6.20 DR25 Dosing system parameters ..........................................................................................98
6.20.1 Maximum single set point [maximumSingleSetPoint] ............................................................98
6.20.2 Minimum automatic tare weight (% of max.) [minimumAutomaticTareWeight]......................98
6.20.3 Maximum automatic tare weight (% of max.) [maximumAutomaticTareWeight]....................98
6.20.4 Maximum weighing time (s) [maximumDosingTime]..............................................................99
Table of contents
Technology module TM SIWAREX WP351 HF
6 Operating Instructions, 01/2020, A5E47521010-AA

Table of Contents

Other manuals for Siemens SIMATIC ET 200SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC ET 200SP and is the answer not in the manual?

Siemens SIMATIC ET 200SP Specifications

General IconGeneral
System TypeDistributed I/O System
MountingDIN Rail
Communication ProtocolPROFINET, PROFIBUS
IP RatingIP20
CategoryI/O Systems
Supply Voltage24 V DC
ModularityYes
Hot SwappingYes
Storage Temperature-40°C to +70°C
Digital InputsYes
Digital OutputsYes
Analog InputsYes
Analog OutputsYes
Communication InterfacePROFINET, PROFIBUS
Number of ModulesUp to 64
Relative Humidity5 to 95% (non-condensing)
Operating Temperature-25°C to +60°C