Maintaining and servicing your device
7.4 Removing and installing hardware
SIMATIC IPC677E
106 Operating Instructions, 04/2019, A5E45117996-AA
7.4.6 Replacing the processor
Requirement
The device is disconnected from the mains and all connecting cables have been
removed.
The device is open, see important information regarding this under Opening the Device
(Page 71).
The memory modules have been removed.
The air guide has been removed (see chapter "Replacing device fans (Page 92)").
An original spare part, i.e. a processor of the same type.
Only an approved processor is permitted to be installed on the motherboard.
NOTICE
Damage to the processor
If the installed processor is operated with a higher clock frequency than permitted, it can be
destroyed or cause loss of data.
Operate the processor only at a clock frequency that is equal to or less than the
permitted clock frequency.