Parameter Description
p9582 Brake ramp delay time (factory setting: 250 ms)
p9583 Brake ramp monitoring time (factory setting: 10 s)
The gradient of the braking ramp depends on p9581 and p9583.
r9714 Speed diagnostics [rpm]
[0] Load-side speed actual value
Electrical speed of the motor. For induction motors, the mechanical speed is ob‐
tained from the electrical speed and slip.
[1] Actual SAM/SBR speed limit
[2] Actual SLS speed limit
r9722.04 Status signals
1 signal: SLS active
0 signal: SLS not active
r9733 Effective setpoint speed limiting
[0] Positive setpoint limitation
[1] Negative setpoint limitation
[2] Absolute setpoint speed limitation
Commissioning
5.12 Setting extended functions
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD 187

Table of Contents

Other manuals for Siemens SINAMICS G120C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS G120C and is the answer not in the manual?

Siemens SINAMICS G120C Specifications

General IconGeneral
Communication InterfacesPROFINET, PROFIBUS, USS, Modbus RTU
Protection ClassIP20
Ambient Temperature-10°C to +50°C
Storage Temperature-40°C to +70°C
Power Range0.55 kW to 132 kW
Voltage Range380 V to 480 V
Output Voltage0 V to Supply Voltage
Frequency Range0 Hz to rated output frequency
Control ModesVector control with encoder
ProtectionOverload, overvoltage, undervoltage, short circuit, ground fault
Relative Humidity5% to 95%, non-condensing
AltitudeUp to 2000 m without derating

Related product manuals